1. The following method is best suited for finding the voltage regulation of an alternator
Answer : Potier traingle method
Explanation:-
2. Power factor of an alternator driven by constant prime mover input can be changed by changing its
Answer : Load
Explanation:-
3. A four pole 3 - phase winding is placed in a stator that has 48 slots. The number of slots per pole per phase is
Answer :
Explanation:-
4. In an alternator, if XS is the synchronous reactance. XC is the leakage reactance, then the reactance Xa due to armature flux is given by
Answer : Xa=Xs-Xc
Explanation:-
5. A 3- phase, 4 - pole, 24 slot alternator has its armature coils short pitched by one slot. The pitch factor becomes
Answer : 0.9659
Explanation:-
6. If the field of synchronous motor is under excited, there power factor will be
Answer : Lagging
Explanation:-
7. The starting torque of an induction motor is maximum when
Answer : Rotor resistance equals rotor reactance
Explanation:-
8. At zero slip of an induction motor
Answer : Motor does not run
Explanation:-
9. The term crawling implies that the machine is
Answer : Running stably at speed as low as low as one seventh of its synchronous speed
Explanation:-
10. Running stably at speed as low as low as one seventh of its synchronous speed
Answer : Adding an auxiliary winding in parallel with the main winding
Explanation:-