1. The losses are measured in auto transformer, when it is operating at no load are 150W. Iron losses of this transformer at full load operation are
Answer : 150w
Explain:-
2. During the SC test, power drawn by the primary winding is predominantly observed by
Answer : Copper loss
Explain:-
3. In parallel operation load sharing by transformers is according to
Answer : Pu impedance
Explain:-
4. When speed of alternator is changed from 3600 rpm to 1800 rpm, the generated emf per phase will become
Answer : 1/2
Explain:- EMF generated ∝ Speed of Alternator
N1=3600rpm;N2=1800rpm
N1/N2=E1/E2
3600/1800=E1/E2
E1/E2=2
E2=E1/2
Generated EMF Will become half
5. The regulation of an alternator is
Answer : The increase in voltage when load is thrown off
Explain:-
6. In case of turbo-alternators, rotor is made of
Answer : Forged steel
Explain:-
7. A synchronous motor is supplied a load at unity p.f. If the load on the motor is increased keeping its excitation and terminal voltage\nconstant, then the p.f
Answer : Will become lagging
Explain:-
8. When synchronous motor is running at synchronous speed, the damper winding produces
Answer : No torque
Explain:-
9. While starting a synchronous motor by induction motor action its field winding should be
Answer : Short circuited
Explain:-
10. The stator core of a three phase inductionmotor is laminated in order to reduce the
Answer : Eddy current loss
Explain:-
1 Comments
Good
ReplyDelete